1)Taking outer air and heating it through heat exchanger.
2)Gases containing Ammonia introduced to box and mixed with heated air.
3)Mixed gas heated up to temperatures of initiation for catalyst reaction.
4)During passing through catalytic layers, Ammonia and Oxygen reacted on
catalytic surface to produce Nitrogen and water vapor. (Catalytic Burning
Method)
5)Produced dissociation heat of Ammonia heating outer air at heat exchanger.
6)Nitrogen and water, after cooling, exhausted into air.
Items | Inlet | Exhaust |
Ammonia | 16000 | below 0.1 |
Nitrogen Oxide | 0 | below 50 |
unit;ppm(Volume)
Items | Inlet | Exhaust |
Hydrogen | 10000 | below 0.1 |
Nitrogen Oxide | 0 | below 50 |
unit;ppm(Volume)
Fermentation odor, rotten organics odor and odor
containing ammonia should be decomposed more than 99%
Bad odor from fermented composts, human waste, sewage
sludge, seafood processing, poultry farming, swine keeping, waste water from
farms etc. these odor should be deodorized satisfactory.
Items | Inlet | Exhaust |
Ammonia | 150 | below 0.1 |
Methyl Mercaptan | 1.3 | below 0.0001 |
Methyl Sulfide | 0.85 | 0.0001 |
Trimethylamine | 2.3 | below 0.0005 |
Nitrogen Oxide | 9.4 | 10.0 |
unit;ppm(Volume)
Items | Inlet | Exhaust |
Ammonia | 14 | 1.2 |
Methyl Mercaptan | 2.10 | 0.0049 |
Methyl Sulfide | 53 | 0.29 |
Concentration of Odor (Japan standard) |
170,000 | 55 |
unit;ppm(Volume)
*Data shown as actually observed,not for insurance.
#503 1-6-14, Hashira,
Okazaki-Shi,Aichi
444-0837 (map)
TEL +81-564-64-5567
FAX +81-564-64-2750